Restore your cooling tower without the cost of a new one.
When fill is scaled solid, nozzles are cracked and the structure is rusting, chemistry alone won't bring a tower back. But that doesn't mean you need a new tower. Hydrovida refurbishes towers cell by cell, so your plant stays partly online, often for a fraction of the cost and lead time of a replacement.
Signs your tower needs more than cleaning
- Fill that's collapsed, sagging or scaled solid
- Cracked, missing or plugged distribution nozzles
- Water bypassing the fill or spraying out of the tower
- Worn belts, loose drives or noisy fans
- Rusted supports, louvers or casing
- Leaving-water temperatures climbing even after a cleaning


What a worn-out tower costs you
Cooling capacity.
Damaged fill and plugged nozzles mean the tower can't reach its design temperature, so chillers work harder on the hottest days.
Energy.
Fans and chillers run longer to make up for lost tower performance.
Water and chemicals.
Poor water distribution and leaks waste both.
Risk.
Degraded fill and dead zones collect sludge and biofilm, which raises Legionella risk.
Repair or replace?
Replacement means a big capital project, months of lead time and a crane. Refurbishment replaces the parts that wear out (fill, nozzles, distribution and drive components) and keeps the structure you already own. Restored fill and distribution recover the tower's design approach temperature and airflow, usually at a fraction of the cost of replacement.
We'll tell you honestly when a tower is past saving.

BeforeAfterWhat a refurbishment includes
Work is staged cell by cell with lockout/tagout, so the remaining cells stay in service at reduced capacity.
- Removal of degraded fill, nozzles, belts and tension hardware
- Full interior pressure wash and fill support prep
- New factory fill sheets, packed to manufacturer instructions
- New metering orifices and hot water basin orifice plate kits
- New drive belts and motor adjustment rods, tensioned to spec
We coordinate factory-authorized refurbishment on Baltimore Aircoil (BAC) and comparable equipment.
Built for public agency and federal projects
- California prevailing wage, with certified payroll and DIR registration
- Crews trained in OSHA 30, confined space entry and fall protection
- CSLB C-55 license #1076507
- CA DGS Certified Small Business #2024415
Keep it running after the repair
A refurbished tower stays that way only if the water treatment is right. We can put a treatment program and regular cleaning in place, so the new fill doesn't scale up again.
Where we repair towers
San Diego County, Los Angeles and Orange County, the Inland Empire, Imperial Valley, the Central Valley, the Bay Area and Sacramento, plus Yuma, Reno and Northern Mexico.
Questions
Can you keep part of the tower running during the work?
Yes. We work one cell at a time with lockout/tagout, so the other cells stay in service at reduced capacity.
How do I know if my tower should be refurbished or replaced?
We inspect the structure, fill, distribution and drives, then give you an honest recommendation with costs for both options.
Do you work on prevailing wage projects?
Yes. We perform public agency and federal work under California prevailing wage, with certified payroll and DIR registration.
Which tower brands do you work on?
We coordinate factory-authorized refurbishment on Baltimore Aircoil (BAC) and comparable equipment.