Process and cooling water treatment that keeps the line running
In manufacturing, a water problem is a production problem. Overheating equipment, a plugged heat exchanger or a boiler trip costs far more in lost output than the treatment program ever will. Hydrovida protects the systems your line depends on.
What it's costing you
Unplanned downtime when heat exchangers, molds or process coolers scale up or plug
Energy lost to scale on chillers, towers and boilers
Corrosion in closed loops and process piping, which shows up as leaks and failed pumps
Quality issues when process water isn't consistent, especially for plating, rinsing and aerospace finishing
Discharge limits on rinse and process wastewater
Where water problems hide in a plant
- Process coolers, molds and heat exchangers that scale or plug a little more every week
- Closed loops that lose inhibitor every time a leak is topped off
- Boilers and steam systems that nobody tests between service calls
- Rinse and plating water that drifts out of spec
- Wastewater that creeps toward its discharge limits as production grows
How Hydrovida helps
Cooling tower and process cooling treatment to keep heat transfer surfaces clean
Closed loop treatment with LTec corrosion inhibitors
Boiler and steam treatment with BTec chemistry
RO and purified water support for rinse and process water
Wastewater treatment with Perfloc coagulants and flocculants
Corrosion coupon monitoring so you see the actual corrosion rate in your piping
The chemistry behind it
- CTec inhibitors and rotating biocides for cooling towers and open process cooling
- LTec molybdate, nitrite and silicate inhibitors for closed process loops, plus LTec cleaners for loops already full of rust
- BTec oxygen scavengers, internal treatments and condensate amines for boilers and steam
- Solutec antiscalants for RO systems that make rinse and process water
- Perfloc coagulants and flocculants for wastewater and sludge
When something fails, we find out why
Our lab runs SEM/EDS, ATR-IR and GC-MS to identify deposits, corrosion products and unknown compounds, so a recurring failure gets fixed at the cause, not patched again. Standard turnaround is 5–7 business days, with rush available.
What you get
- Scheduled service with a written report every visit
- Lab analysis from our in-house laboratory
- Records that support your quality and customer audits
FAQ
Can you treat process cooling loops, not just towers?
Yes. We treat open and closed process cooling, chillers and heat exchangers.
Can you help with discharge permits?
Yes. We test wastewater, recommend treatment and help keep you within your limits.
Can you identify a deposit or residue that's showing up in our process?
Yes. Our lab identifies deposits, corrosion products and unknowns with SEM/EDS, ATR-IR and GC-MS, and tells you where they're coming from.
Do you train our maintenance staff?
Yes. We train your team on site at your equipment, as often as you need, and document every session.
- 120+
- Facilities served
- $36K
- Average yearly savings per customer
- 30%
- Average water reduction
- 0
- Customers lost to performance
Averages across Hydrovida customers.
Find the water problem before it stops the line
Talk to a Hydrovida engineer about your system — no obligation, no cost.
or call (866) 808-3315.