Water treatment for power, energy and utility plants

Whether it's a peaker plant, a cogeneration unit or a data center, cooling and makeup water decide whether you hit your capacity on the hottest day of the year. Hydrovida keeps heat transfer surfaces clean, makeup water in spec and water use as low as your water allows.

Request a free water analysis

What's at stake

  • Capacity and heat rate: scale and fouling in condensers and towers cut output when demand peaks.

  • Water supply: California plants face tight water budgets and rising costs. Every cycle of concentration counts.

  • Boiler and HRSG reliability: oxygen pitting and deposits lead to tube failures and forced outages.

  • Makeup water quality: RO and demineralizer systems that foul or scale raise operating costs.

  • Discharge limits on blowdown and process water.

Built for plants that run hardest on the hottest days

Peak demand, peak heat and peak cooling load all arrive together. A tower that scales up in spring costs you capacity in August. We set treatment for your worst-case load, not your average one, and adjust as conditions change through the season.

How Hydrovida helps

  • Cooling tower treatment at the highest safe cycles, with controllers and monitoring

  • Boiler and steam treatment for oxygen control and deposit prevention

  • RO pretreatment, antiscalants and membrane cleaning for makeup water

  • Blowdown reuse: treating tower blowdown with RO so it can be reused

  • Membrane autopsy and lab diagnostics to find the root cause of fouling

The chemistry and equipment behind it

  • CTec inhibitors and rotating biocides for condenser cooling towers
  • BTec oxygen scavengers, internal treatments and amines for boilers and HRSGs
  • Solutec antiscalants and Synetec cleaners for RO makeup systems, including Solutec Si for high-silica water
  • Controllers with remote monitoring, so we see conductivity, pH and inhibitor levels between visits
  • Corrosion coupons that measure actual corrosion rates in mils per year

Turning blowdown into makeup water

Cooling tower blowdown doesn't have to go down the drain. With the right pretreatment and RO, part of it can be recovered and reused as makeup, cutting both water purchases and discharge. We test your blowdown and scope what a reclaim system would take.

Questions

FAQ

Can you support temporary or mobile cooling?

Yes. We treat trailer-mounted and temporary cooling units as well as permanent towers.

Do you offer remote monitoring?

Yes. Controllers with remote monitoring let us see conductivity and feed rates between visits.

Do you serve data centers?

Yes. We treat data center cooling towers and closed cooling loops, with remote monitoring available.

Can you help us reuse cooling tower blowdown?

Often, yes. We test the blowdown and scope the pretreatment and RO needed to reuse it as makeup water.

120+
Facilities served
$36K
Average yearly savings per customer
30%
Average water reduction
0
Customers lost to performance

Averages across Hydrovida customers.

Start a Conversation

Run more cycles and buy less water

Talk to a Hydrovida engineer about your system — no obligation, no cost.